Fuel Feed Related Problems

  All England's stove works pellet units use a two auger feed system. This system feeds the fuel though at a rate determined by the control board settings. The upper auger located at the bottom of the hopper runs intermittently. The lower auger which brings the pellets from the upper auger to the fire runs continuously.
  Each of the augers is independently run by a motor and gearbox assembly. These motors are identical and interchangeable. Feed related issues fall under two categories; bottom auger stopped, or bottom auger turning but no fuel is being fed.
  Lower auger not turning.
If the lower  auger is not turning the following should be checked; 1. Is the auger physically jammed? Foreign objects such as wood chips or other objects that may have somehow gotten into the pellets. 2. Is the motor getting power? If the motor is getting power it will get fairly hot quickly. If the motor is getting power but is not running and the auger is not jammed, the motor is bad. If the motor is not getting power, either the motor's wires or the control board are bad. Another possibility is if the electric motor is running but the auger is not turning, this could be a loose setscrew holding the motor to the auger, or a stripped gear in the gearbox. A stripped gear would mean the auger  motor must be replaced.
  The lower auger is turning but no fuel is coming out. If this is the case, the first thing that should be done is the hopper should be emptied. Check the auger itself to see if it is physically jammed as foreign objects in pellets could jam the auger. If the auger is free the next step would be to determine if the motor is receiving power. The motor will get warm if it is getting power within a few minutes. If the motor is getting power and is not running the motor is bad. If it is not receiving power the next step is to check the wiring. the wires from the top auger motor are connected on terminals 3 and 4 on the control board from left to right). Another possibility could be the over temperature limit protection in the control board. This will stop the top auger if the unit reads as being too hot, the auger will start moving again if the unit cools to an acceptable temperature however and generally will continue to operate.


The vacuum switch to the left in this picture is wired through the top auger motor.

Note:

The model shown in the picture is the model 25-pdvc/55shp10/55trp10.
In models 25-pdv/55-shp22 /55-trp22, and models 25-pi/ 55-shp20/ 55-trp20 the vacuum switch wired through the top auger circuit is located forward in the back of the stove beneath the room air blower.

Vacuum related stoppages

  The "door ajar" vacuum switch present in newer model pellet units is wired through the top auger motor and works through vacuum pressure pulled from the firebox by means of a vacuum hose. If this hose is plugged disconnected, or damaged, the top auger will not run.

Click Here for Wiring Page

Click Here for Feed Rate /Thermostat Problems Page

Click Here for Auger Alignment Page

If you have any further questions or concerns, please contact Customer Service at:
1-800-245-6489

Copyright © 2005   England's Stove Works, Inc.   All rights reserved.
Revised:  11/07/2008

This web site, including all pictures, description and information of any sort contained therein is intended for the sole use of customers and representatives of England's Stove Works, Inc. No part of this web site or the information contained therein may be reproduced without express written permission from England's Stove Works, Inc..